WEBVTT

00:00:00.256 --> 00:00:02.219
Hi, I'm Steve Smith with Camper Van

00:00:02.219 --> 00:00:04.608
Freedom. A roof vent shares space with

00:00:04.608 --> 00:00:06.294
the solar panels, rack,

00:00:06.357 --> 00:00:07.680
brackets and cable routes,

00:00:07.680 --> 00:00:10.411
and its ceiling position matters inside too.

00:00:10.624 --> 00:00:12.800
I bought the MAXXAIR sixty-two hundred K

00:00:12.800 --> 00:00:15.602
manual-opening fan. My roof-planning guide starts with

00:00:15.602 --> 00:00:18.248
one coordinated drawing, then checks the fan's

00:00:18.248 --> 00:00:20.765
opening, surrounding space and the place from

00:00:20.765 --> 00:00:22.547
which I will reach its controls.

00:00:22.748 --> 00:00:24.583
Use one reference for the roof plan,

00:00:24.583 --> 00:00:25.800
such as the front of the usable

00:00:25.820 --> 00:00:27.826
roof area and the vehicle centerline.

00:00:27.868 --> 00:00:29.085
Label front and rear,

00:00:29.106 --> 00:00:31.111
and keep the roof-side drawing aligned with

00:00:31.111 --> 00:00:32.703
the interior ceiling view.

00:00:32.843 --> 00:00:34.421
Separate the features already there,

00:00:34.421 --> 00:00:36.042
the equipment to place and the room

00:00:36.042 --> 00:00:37.473
needed to reach or move it.

00:00:37.536 --> 00:00:40.011
Keep measured dimensions beside the outlines rather

00:00:40.011 --> 00:00:42.229
than chaining positions from one movable item

00:00:42.229 --> 00:00:44.554
to another. Record the small parts as

00:00:44.554 --> 00:00:46.004
well as the large equipment.

00:00:46.004 --> 00:00:49.290
Rails, crossbeams, brackets, panel supports,

00:00:49.290 --> 00:00:52.319
junction boxes, glands and conduit all compete

00:00:52.319 --> 00:00:55.121
for space. My roof-work notes include power

00:00:55.121 --> 00:00:57.766
leads and camera Ethernet routes alongside the

00:00:57.766 --> 00:01:00.625
panel fitting. A wide photograph locates the

00:01:00.625 --> 00:01:04.157
arrangement, while close-ups explain an individual connection.

00:01:04.274 --> 00:01:05.896
Keep the boxes and cable exits on

00:01:05.896 --> 00:01:07.261
the same plan as the panels and

00:01:07.261 --> 00:01:09.310
fan. Draw the fan opening,

00:01:09.437 --> 00:01:12.439
outer flange and rear clear space separately.

00:01:12.581 --> 00:01:14.714
The U S MAXXFAN Deluxe manual that

00:01:14.714 --> 00:01:17.487
includes the sixty-two hundred K specifies a

00:01:17.487 --> 00:01:20.757
fourteen-by-fourteen-inch opening. It also calls for at

00:01:20.757 --> 00:01:23.019
least eight inches clear behind the flange's

00:01:23.019 --> 00:01:25.451
outer rear edge, with the louvers facing

00:01:25.451 --> 00:01:28.395
the vehicle's rear. The rear-space mark starts

00:01:28.395 --> 00:01:29.825
at that flange edge,

00:01:29.845 --> 00:01:31.092
not at the opening.

00:01:31.271 --> 00:01:33.490
Keep the exact model and manual reference

00:01:33.490 --> 00:01:35.623
beside the drawing. Check the ceiling side

00:01:35.623 --> 00:01:36.755
of the same position.

00:01:36.946 --> 00:01:38.909
My sixty-two hundred K has a manually

00:01:38.909 --> 00:01:40.904
opened lid and ceiling controls.

00:01:41.021 --> 00:01:43.496
Mark the trim area and nearby furniture,

00:01:43.538 --> 00:01:45.373
then consider the floor position used to

00:01:45.373 --> 00:01:47.187
reach upward. Include doors,

00:01:47.208 --> 00:01:49.100
lids and other moving furniture.

00:01:49.200 --> 00:01:51.034
A convenient location on the roof can

00:01:51.034 --> 00:01:53.168
create a different access question inside,

00:01:53.338 --> 00:01:55.002
so keep both views aligned when a

00:01:55.002 --> 00:01:57.996
position changes. My panel trial fit involved

00:01:58.059 --> 00:02:00.320
moving the existing rack crossbeams to suit

00:02:00.320 --> 00:02:03.136
panel length, adding twenty-twenty extrusion above the

00:02:03.136 --> 00:02:05.014
rack and bringing two panels up for

00:02:05.014 --> 00:02:07.617
fitting. That session also included the small

00:02:07.617 --> 00:02:10.729
passenger-side lights. Work through the supports first,

00:02:10.835 --> 00:02:13.204
then large equipment and its surrounding space,

00:02:13.310 --> 00:02:15.081
then boxes and cable routes.

00:02:15.230 --> 00:02:17.278
Revisit the ceiling view and photograph the

00:02:17.278 --> 00:02:19.211
revised arrangement when something moves.

00:02:19.351 --> 00:02:22.338
Compare control arrangements separately from my purchase.

00:02:22.465 --> 00:02:24.982
The MAXXAIR seventy-five hundred K is a

00:02:24.982 --> 00:02:27.713
researched alternative with remote control and thermostat

00:02:27.713 --> 00:02:30.680
functions. The Fan-Tastic twelve hundred is another

00:02:30.680 --> 00:02:32.899
alternative with a manual lid crank and

00:02:32.899 --> 00:02:36.397
three-speed ceiling control. Those alternatives are comparison

00:02:36.397 --> 00:02:38.957
options; my purchased fan was the sixty-two

00:02:38.957 --> 00:02:41.066
hundred K. Each model keeps its own

00:02:41.066 --> 00:02:43.755
product record, image and equipment dimensions.

00:02:43.925 --> 00:02:45.802
Thanks for watching. I'm Steve Smith with

00:02:45.802 --> 00:02:48.440
Camper Van Freedom. My roof worksheet records

00:02:48.440 --> 00:02:50.339
the position reference, opening,

00:02:50.403 --> 00:02:53.774
outer envelope, moving or clear-space envelope,

00:02:53.816 --> 00:02:55.971
nearby equipment and next check.

00:02:56.163 --> 00:02:57.721
Add the result to the same row

00:02:57.741 --> 00:02:59.373
and date the revised plan.

00:02:59.468 --> 00:03:02.221
The full guide, original roof-work photographs,

00:03:02.241 --> 00:03:05.165
worksheet and component references are linked below.

00:03:05.313 --> 00:03:06.402
Until next time.